Frequently Asked Questions

Home | Frequently Asked Questions | FAQs for Draining a Decontamination Unit in Winter

FAQs for Draining a Decontamination Unit in Winter

FAQs for Draining a Decontamination Unit in Winter

Q: Why is it necessary to drain the decontamination unit during winter? A: Draining the decontamination unit in winter is crucial to prevent the water inside from freezing, which can lead to expanded and potentially cracked pipes, causing damage to the system. It also helps avoid delays due to frozen pipes that must be thawed before use.

Q: When should I drain my decontamination unit? A: You should drain your decontamination unit if it stands idle during winter, even if it’s just for a couple of hours in colder temperatures, to prevent any water from freezing in the system.

Q: How do I drain the water tank in the decontamination unit? A: Locate the valve next to the water tank and open it by turning it anti-clockwise. Let the water run out entirely, then wipe the area dry.

Q: Where can I find the sinks, showers, and boiler valves? A: The valves are generally located as follows:

  • For sinks and showers, underneath the facilities.
  • For the boiler, there is an external storage cupboard at the front of the unit. The locations may vary depending on the unit’s size, make, model, and age.

Q: What should I do if there are large volumes of water to drain? A: If there are large volumes of water, it is recommended to open the system close to a drain to manage the water disposal safely. Always ensure you are complying with local regulations regarding water disposal.

Q: How do I open the valves? A: Valves are typically opened by turning them anti-clockwise. Many valves will have markings or signs to guide you.

Q: What happens if I don’t drain the decontamination unit before moving it? A: Failing to drain all water can cause an imbalance in the unit during transport, potentially leading to damage such as a cracked chassis.

Q: How often should I drain the decontamination unit? A: It is good practice to drain the unit regularly during winter or any cold spell and at the end of a project before the unit is moved.

Q: What if I need assistance with my decontamination unit? A: If you need assistance, Beacon International offers a range of decontamination units for purchase or hire, and you can contact their team for support with your current unit or product inquiries.

Q: Can I leave the unit undrained if I have antifreeze in the system? A: Relying on antifreeze alone is generally not recommended, as it may not provide adequate protection in all system parts. Draining the unit is the most reliable method to prevent freeze damage.

We hope these FAQs for Draining a Decontamination Unit in Winter have provided you with valuable insights and practical solutions for maintaining your decontamination unit during the winter months. For your convenience and to ensure you cover all essential steps, we invite you to download our comprehensive Winter Maintenance Checklist. This handy resource is designed to assist you in keeping your decontamination unit in optimal condition, preventing any winter-related issues. Download now and take a step towards hassle-free winter maintenance with Beacon International.