DOP Testing
and Servicing
At Beacon International we have the expertise to service and
D.O.P. all makes of asbestos removal equipment.
All Negative Pressure Units and “H” Type Vacuum
Cleaners MUST be D.O.P. tested:
- Every six months whether they have been used or not.
- If the machine has been dropped or damaged in any way.
Our philosophy is that just testing a machine
is not enough. At Beacon International we offer comprehensive
service facilities.
Transport
Collect and return service
is available covering the whole of England and Wales.
Service records
Your machine will
be booked into our customer database from which we will generate
a service report, test certificates and service reminders.
Each service carried out becomes a permanent record on our
system where we store test results, customer and plant details.
Replacement certificates can be generated should you loose
the originals.
A service reminder will be sent to you approximately three
weeks before the next service is due.
Decontamination
Every machine goes through our purpose built
decontamination unit where it will be thoroughly cleaned, bags
and pre filters will be replaced as required and the H.E.P.A.
filter will be visually inspected.
Once the machine has fully decontaminated, motors and internal
wiring will be checked.

Testing
Finally every machine is:
DOP TESTED (Dispersed Oil Particulate)
This will confirm that there are no leaks in the HEPA filter
or the seals inside the machine.
P.A.T. TESTED (Portable Appliance Testing)
This checks that there is an earth bond.
AMPERAGE TESTED.
Gives you an amperage reading, which lets you know which size
transformer you will need.
AIRFLOW TESTED (NPU)
We can determine if your HEPA filter is blocked from this test.
VACUUM TESTED (Vacs)
The amount of vacuum created tells us if your HEPA filter and
support bags are in good order.
Our engineers will advise you of blocked
HEPA (High Efficiency Particle Arrestors) Filters which potential
can burst as illustrated to the right.
On site testing
In some cases it is not possible for equipment
to be returned to Beacon.
We offer on site testing where we will carry out the same tests
as in the workshop, on site repairs cannot be undertaken as
stated in working with asbestos regulations. available at request.
Our engineers will test
your equipment on site, any failures should be returned to
Beacon for repair.
Please note in order us to test machines on site, clean paper
bags MUST be fitted to Vacuum Cleaners and clean pre filters
MUST be fitted to NPU’s before they are released from
the enclosure.
|